ELECTRO ACUPUNCTURE: ACUPUNCTOSCOPE Model WQ-10D1

The product you selected is currently unavailable.

Price: $135.42
Availability: in stock
Prod. Code: WQ-10D1

 

Electro Acupuncture 
Machine  Model WQ10-D1

The Multiple Electronic Acupunctoscope (MEA), Model WQ-10-D1 is an instrument used both as a detector of acupuncture points and as an electrical stimulator for acupuncture therapy and anesthesia. The WQ-10D1 model is a newly modified unit from the older WQ-10 series acupunctoscope, featuring a CA(constant amplitude)-AM(amplitude modulation) selecting switch to allow it to discharge six different combinations of wave patterns.
WQ10 D1, WQ10D1, Electro Acupuncture, Acupuncture Machine, Electro Atimulator,
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Electronic Acupunctoscope Feature:
WQ-10C2
WQ-10D1
Multiplier Kx1 / Frequency f(c/s) 0~100 / Width T(µs) 250 ~ 300Multiplier Kx10 / Frequency f(c/s) 0~1000 / Width T(µs) 50 ~ 60
Frequency f(c/s) 0~100 / Width T(µs) 250 ~ 400
I. The adjustment of the stimulating wave forms and frequencies. They are controlled by following knobs and switch:
F1=fixed frequencies
F2=variable frequencies
K=multiplier
There are two positions on switch k, “x1” and “x0.1”. The frequency of output impulse, F=Kfi, can be adjusted within two different ranges, (0~100Hz and 0~10Hz). There are 3 different forms of combinations by using f1 and f2:
1.When f2 is at 0, by adjusting f1, a continuous wave is obtained.
2. When f2 is at 0, by adjusting f2, an intermittent wave is obtained.
3. By adjusting f1 and f2, but keep f1
I. The adjustment of the stimulating wave forms and frequencies. They are controlled by following knobs and switch:
F1=fixed frequencies
F2=variable frequencies
CA (constant amplitude)-AM(amplitude modulation) selecting switch.
CA (constant amplitude)-AM(amplitude modulation) selecting switch.
There are six different forms of combinations by using f1 and f2 CA-AM
1. When f2 is at 0, by adjusting f1, a continuous (CA) or rise-fall(AM) wave is obtained.
2. When f1 is at 0, by adjusting f2, an intermittent (CA) or saw tooth (AM) wave is obtained.
3. By adjusting f1 and f2, but keep f1
WQ10D1, WQ10 D1, WQ10-D1, Electro Acupuncture, Acupuncture Machine, Electro Stimulator
WQ10D1, WQ10 D1, Electro Acupuncture, Acupuncture Machine, Electro Stimulator,
II. Acupuncture therapy and anesthesia
1. Set “Intensity” knob to zero and “E-E or APD” switch to “1.2.3”, set “Hi-Lo” switch to “Hi” or “Lo” position as required. Intensity of “Lo” position is 1/3 of “Hi”.
2. Plug output leads into 1.2.3 sockets, then fasten their clips to the handles of the needles.
3. Set the desirable waveforms and frequencies with knobs f1, f2 and K.
4. Turn “on” main switch
5. Adjust intensity to appropriate degree
 
II. Acupuncture therapy and anesthesia
1. Set “Intensity” knob to zero and “E-E or APD” switch to “1.2.3”, set “Hi-Lo” switch to “Hi” or “Lo” position as required. Intensity of “Lo” position is 1/3 of “Hi”.
2. Plug output leads into 1.2.3 sockets, then fasten their clips to the handles of the needles.
3. Set the desirable waveforms and frequencies with knobs f1, f2 and K.
4. Turn “on” main switch
5. Adjust intensity to appropriate degree
 
III. Therapy with Electric, Excitatory(E-E) and 'skin sure' face acupuncture point stimulation:
1. Use output leads with banana plugs. Connect the bananas plugs with probes provided with cup shaped electrodes at terminal ends. Fill the cup with absorbent cotton soaked with salt solution. Fix the cup electrode onto the acupuncture points or the other selected parts of the skin. Set “Hi-Lo” switch to “Hi” position.
2. In case of weak stimulation follow the same steps described in II. Plug output leads into 1.2.3 sockets.
3. For strong stimulation, the output will be taken from the “E-E or APD” socket, which is specially designed for this purpose. Set”E-E or APD” switch to “E-E1+2+3” position and intensity is regulated by 1.2.3 channels together.

IV. Detection of “Meridian Sensitivity”
Subjects are found to be more sensitive to acupuncture. A particular sensation traveling along the pathways of meridians is demonstrated when the “Ching-Hsueh” (at the terminal parts of four limbs) is stimulated with electric impulse of appropriate intensity. This sensation is termed the meridian sensation. In most sensitive subjects the meridian sensation can travel along the pathway of the meridian and sometimes even extends to the neighboring meridian . The meridian sensitivity varies with different subjects, while the intensity of the electric excitation required to produce this particular sensation varies from person to person. Subjects who show more “meridian sensitivity” always react to acupuncture therapy and anesthesia with better results than those who are insensitive to it. 
III. Therapy with Electric, Excitatory(E-E) and skin sure face acupuncture point stimulation:
1. Use output leads with banana plugs. Connect the bananas plugs with probes provided with cup shaped electrodes at terminal ends. Fill the cup with absorbent cotton soaked with salt solution. Fix the cup electrode onto the acupuncture points or the other selected parts of the skin. Set “Hi-Lo” switch to “Hi” position.
2. In case of weak stimulation follow the same steps described in II. Plug output leads into 1.2.3 sockets.
3. for strong stimulation, the output will be taken from the “E-E or APD” socket, which is specially designed for this purpose. Set”E-E or APD” switch to “E-E1+2+3” position and intensity is regulated by 1.2.3 channels together.
 
WQ10D1, WQ10 D1, WQ10-D1, Electro Acupuncture, Acupuncture Machine, Electro stimulator, 1. Power Supply ON/OFF
2. Knob Sensitivity of Adjustment
3. Fixed Frequency
4 . Variable Frequency Switch
4. Stimulating Output Socket
5. CA / AM Selecting Switch for WQ-10D1
0 0x0.1 / x1 Selecting Switch for WQ-10C2
6. Frequency Indicator Green LCD Light
7. Adjustable Intensity
8. E - E or APD Socket
9. 10.11. Stimulating Output Socket
12.Inject for AC Adapter ( Adaper not included )
13.Electric Excitatory or Acupuncture Points
000Detection Selecting Switch
 
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1. Multiple usages:A. The section used for acupuncture point detection can also be used for locating the auriculo-acupuncture points, meridian points, and band of (?) zone of acupuncture points.
B. The section used for stimulation can also be used for acupuncture therapy, skin surface acupuncture point stimulation, electrical Ti-Needle, acupuncture anesthesia, therapy by electric excitation, and measuring the sensitivity of meridian.
Both A and B sections maybe used at the same time.

2. Multiple transmit messages:
The instrument can transmit three waveforms of impulse series. Their frequency varies from 0-100 C/S, with several adjustment combinations. By varying the combinations of these differing massage types, a large number of stimulating conditions may be derived in order to prevent repetitious overuse, enhancing therapeutical efficiency.
3. High intensity of output: divided into "High" and "Low" two ranges, smooth adjustment, high stability and low power consumption.
4. Detecting acupuncture points with accuracy and without producing pain sensation. After the location of point, stimulating pulses can also provide therapy from the detecting probe.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WQ10D1, WQ10 D1, WQ10-D1, Electro Acupuncture, Acupuncture Machine, Electro stimulator,
000
WQ10D1, WQ10 D1, WQ10-D1, Electro Acupuncture, Acupuncture Machine, Electro stimulator,
Accessories
Output leads with clips ( 3 sets)
Output leads with banana plugs ( 1 set)
Ground pole (1 pc.)
•  Cup-shaped electrode for electric excitation (1 pcs.)
•  Probe attachment with a cylindrical electrode for detection of "meridian sensitivity" at one end and a conical head for acupuncture points detection at the other ( 1 pc.)
•  Monitoring loudspeaker (1 pc.)
  0000WQ-10D1

Please note: this listing is for  the model WQ-10D1